Skip to content
Krohne Flow Meter

OPTISONIC 7300

Technology: Ultrasonic

2-path ultrasonic gas flowmeter for natural gas, hydrogen, process and utility gas, with a 100:1 turndown and no pressure loss.

The OPTISONIC 7300 measures gas flow with the transit time differential principle and reports standard volume flow, largely independent of gas density and composition. It is used in refineries, chemical and petrochemical plants, and for non-custody transfer natural gas, hydrogen, compressed air, mixed and flue gases up to +180°C / +356°F. The full bore design has no moving parts, no wear and no pressure loss, and it measures in both flow directions. Current inputs take external pressure and temperature signals for volume correction to standard conditions, and the built-in OPTICHECK technology provides diagnostics and a one-click verification report via HART using the OPTICHECK DTM.

Specifications

Measuring Principle
Transit time differential, 2-path
Flange Size
DN50…1000 / 2…40"
Max. Pressure Rating
PN450 / ASME Cl 2500
Process Connections
Flange; also weld-in connections
Turndown Ratio
100:1
Max. Gas Temperature
+180°C / +356°F
Outputs / Communication
3 x 4…20 mA, HART, Modbus, FF
Transducer Material
NACE-approved grade 29 titanium
Optional Transducer Materials
Stainless steel / composite or Inconel for hydrogen and oxygen service
Versions
Compact (7300 C) or field-mount (7300 F)

Enquire about this product

Pricing, availability, lead times and technical support — direct from our engineers.

Flow Measurement — talk to our engineers

Flowmeters, controllers and accessories for every process