POWERFLUX 5300
Technology: Electromagnetic
Nuclear-grade electromagnetic flowmeter with ceramic measuring tube for demanding liquid applications up to 40 barg.
The POWERFLUX 5300 is an electromagnetic flowmeter engineered for nuclear applications, combining a robust ceramic measuring tube (ZrO2 or Al2O3) with reliable performance across a wide process temperature range of -40 to +180°C. Designed to withstand pressures up to 40 barg, it supports nuclear qualification on request in accordance with standards such as ASME III and RCC-M/E. Flexible connectivity is ensured through a comprehensive range of analogue, discrete and digital output options, including HART, PROFIBUS, FOUNDATION Fieldbus, Modbus RTU and PROFINET, enabling seamless integration into critical process control systems.
Specifications
- Product type
- Flowmeter
- Product family name
- POWERFLUX
- Product positioning
- For nuclear applications
- Measurement principle
- Electromagnetic
- Measured media
- Liquids
- Process pressure
- max. 40 barg/580 psig
- Process temperature
- -40...+180°C/-40…+356°F
- Measuring tube
- Ceramic (ZrO2 or Al2O3)
- Certificates/Approvals Nuclear
- Nuclear qualification on request (e.g. acc. to ASME III, RCC-M/E, etc.)
- Analogue outputs
- 4…20 mA
- Discrete outputs
- Limit switches, Pulse, Frequency, Status
- Digital outputs
- FOUNDATION™ Fieldbus, HART®, Profibus-PA, Profibus-DP, Modbus RTU, PROFINET