OPTISWITCH 5300
Technology: Vibrating level switches
Vibrating fork point level switch for liquids from -196 to +450°C and up to 160 barg, used for high/low alarm, overfill protection and pump dry-run detection.
The OPTISWITCH 5300 detects point level in liquids using a corrosion-resistant Inconel 718 tuning fork, with probe lengths up to 3000 mm / 118 ft. It covers process temperatures from -196 to +450°C / -321 to +842°F and pressures from -1 to 160 barg, which meets boiler standards for saturated steam. Liquids with a density of ≥0.47 g/cm³ can be detected, or ≥0.42 g/cm³ with the optional setting. The switch is unaffected by dielectric constant, density or turbulence, needs no adjustment at start-up, and allows a functional test during operation. An optional second ceramic process seal adds safety, and approvals include WHG, NACE, ship, Ex, boiler and SIL (SIL2/3-compliant).
Specifications
- Probe Length
- up to 3000 mm / 118 ft
- Minimum Liquid Density
- ≥0.47 g/cm 3 / 0.017 lb/in 3 (optional: ≥0.42 g/cm 3 or 0.015 lb/in 3 )
- Process Temperature
- -196…+450°C / -321…+842°F
- Process Pressure
- -1…160 barg / -14.5…2321 psig
- Tuning Fork Material
- Inconel ® 718
- Second Process Seal
- Ceramic (optional)
- Approvals
- WHG, NACE, Ship, Ex, Boiler and SIL
- Functional Safety
- SIL2/3-compliant
Enquire about this product
Pricing, availability, lead times and technical support — direct from our engineers.
Related products






Level Measurement — talk to our engineers
Continuous and point level measurement for liquids and solids