Krohne Flow Meter

DWM 2000

Technology: Electromagnetic

3-wire insertion-type electromagnetic flowmeter for conductive liquids, pastes and slurries in DN25…400 pipes, with 4…20 mA output and IP68 option.

The DWM 2000 monitors the flow of conductive media (≥20μS/cm) and indicates flow rate and flow velocity, with a range adjustable from 1…8 m/s. A welding socket is supplied for mounting on pipes DN50…400, an optional spool piece avoids welding on DN25…50 lines, and the long version (DWM 2000 L) covers larger pipes and open channels. It has no moving parts, with wetted parts in stainless steel and ceramic, and the converter can be removed or rotated under process conditions. Options include an IP68 version for immersed measuring points, a VARIVENT connection for hygienic applications, an isolation valve and an LCD display; each unit is factory calibrated.

Specifications

Measuring Principle
Electromagnetic, insertion-type
Minimum Conductivity
≥20μS/cm
Process Temperature
-25…+150°C / -13…+302°F
Maximum Pressure
up to 25 barg / 360 psig
Pipe Size
DN25…400 / 1…16", optional >DN400 / 16"
Velocity Range
adjustable 1…8 m/s or 3.3…26.2 ft/s
Output
3-wire, 4…20 mA
Ingress Protection
IP68 (immersed applications)
Wetted Parts
Stainless steel and ceramic
Welding Socket Pipe Size
DN50…400 / 2…16"
Spool Piece Pipe Size
DN25…50 / 1…2" (optional)
Hygienic Connection
VARIVENT (optional)
Display
Optional LCD indication

Enquire about this product

Pricing, availability, lead times and technical support — direct from our engineers.

Flow Measurement — talk to our engineers

Flowmeters, controllers and accessories for every process