Orifice plate assembly with ASME 16.36 measuring flanges, RF sealing face and flange taps for DP flow measurement of liquids, gases and steam.
The OPTIBAR OP 5100 is a differential-pressure flow element built around an orifice plate and a pair of measuring flanges with integrated taps. It is supplied pre-assembled with gaskets, bolts, nuts and jack screws for separating the flanges during plate inspection. Taps are typically 1/2" or 3/4" with BWE, threaded or flanged connections, and can be fitted with condensate chambers and shut-off valves. Sizing follows EN ISO 5167, ASME MFC-3M, AGA 3, ASME PTC 19.5 2004, GOST 8.586 or RD 50-411-83, and the plate can be replaced without changing the carrier assembly.
Specifications
- Product type
- Primary flow element
- Product family name
- OPTIBAR
- Product positioning
- With measuring flanges (ASME 16.36)