SA series - Grapes Analyzer
Automatic at-reception grape must analyzer measuring sugar content, pH, total acidity and colour in a single fast cycle.
The SA series analyzer automates sampling, measurement and washing to characterize incoming grape must right at the receiving dock, cutting waiting times to just minutes per truck. Starting from a standard Brix-only configuration, the modular design lets wineries add pH, total acidity, colour (PQ/Tonality) and sanity measurements as needs grow. Results can be sent to a printer, plant management system or a farmer-facing remote display, and the unit connects directly to Maselli's CC05 truck sampling probe for fully automatic operation with a single operator.
Specifications
- Application:
- Measure and analysis, in cycles with automatic loading, of a sample of grape must at the time of reception of grapes
- Limits/measurement scale:
- 0…18% vol. calculated conventionally on the basis of 16.83 g/l per 1% in volume of alcohol
- Accuracy:
- ±0.1% vol. maximum tolerated error is applied to indications which are not rounded off
- Concentration measurement:
- For instruments marketed in countries where type analysis is not envisaged
- PQ/Tonality measurement
- Measurement limits: PQ: 90…250 unità PQ Tonality: 0…2.5 Accuracy: PQ: 1 PQ unit Tonality: ±0.03
- Notes:
- The measurement is to be considered that on a turbid product (i.e. must)
- pH measurement
- Measurement limits: 2…14 pH Accuracy: ±0.05 pH unit
- Total acidity analysis
- Measurement scale span: 0…30 g/l of tartaric acid Accuracy: 0.10 g/l of tartaric acid
- Product temperature:
- 5…40 °C with automatic compensation of the temperature measured with Temperature Sensor Pt1000 in INOX 304, Class “A” in accordance with IEC751
- Quantity of analyzed sample:
- 500 cc for concentration measurement, 50 cc for analysis of pH and Total Acidity. In the version SA01/13, total quantity = ~630 cc
- Quantity of sample transferred:
- ~1500 cc/analysis cycle
- Capacity of transfer tank:
- ~5 litres; minimum 2 litres per cycle
- Cycle duration:
- Variable in accordance with time required for collection from trailer by the operator and programmed print parameters. Minimum 70 s, mean 90 s.
- Consumables:
- NaOH 2% Consumption ~5 ml/Analysis; pH4 and pH7 calibration solutions, Consumption ~25 cc. each/24 h